new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

May 11

Whole Heart 3D+T Representation Learning Through Sparse 2D Cardiac MR Images

Cardiac Magnetic Resonance (CMR) imaging serves as the gold-standard for evaluating cardiac morphology and function. Typically, a multi-view CMR stack, covering short-axis (SA) and 2/3/4-chamber long-axis (LA) views, is acquired for a thorough cardiac assessment. However, efficiently streamlining the complex, high-dimensional 3D+T CMR data and distilling compact, coherent representation remains a challenge. In this work, we introduce a whole-heart self-supervised learning framework that utilizes masked imaging modeling to automatically uncover the correlations between spatial and temporal patches throughout the cardiac stacks. This process facilitates the generation of meaningful and well-clustered heart representations without relying on the traditionally required, and often costly, labeled data. The learned heart representation can be directly used for various downstream tasks. Furthermore, our method demonstrates remarkable robustness, ensuring consistent representations even when certain CMR planes are missing/flawed. We train our model on 14,000 unlabeled CMR data from UK BioBank and evaluate it on 1,000 annotated data. The proposed method demonstrates superior performance to baselines in tasks that demand comprehensive 3D+T cardiac information, e.g. cardiac phenotype (ejection fraction and ventricle volume) prediction and multi-plane/multi-frame CMR segmentation, highlighting its effectiveness in extracting comprehensive cardiac features that are both anatomically and pathologically relevant.

  • 6 authors
·
Jun 1, 2024

CineMA: A Foundation Model for Cine Cardiac MRI

Cardiac magnetic resonance (CMR) is a key investigation in clinical cardiovascular medicine and has been used extensively in population research. However, extracting clinically important measurements such as ejection fraction for diagnosing cardiovascular diseases remains time-consuming and subjective. We developed CineMA, a foundation AI model automating these tasks with limited labels. CineMA is a self-supervised autoencoder model trained on 74,916 cine CMR studies to reconstruct images from masked inputs. After fine-tuning, it was evaluated across eight datasets on 23 tasks from four categories: ventricle and myocardium segmentation, left and right ventricle ejection fraction calculation, disease detection and classification, and landmark localisation. CineMA is the first foundation model for cine CMR to match or outperform convolutional neural networks (CNNs). CineMA demonstrated greater label efficiency than CNNs, achieving comparable or better performance with fewer annotations. This reduces the burden of clinician labelling and supports replacing task-specific training with fine-tuning foundation models in future cardiac imaging applications. Models and code for pre-training and fine-tuning are available at https://github.com/mathpluscode/CineMA, democratising access to high-performance models that otherwise require substantial computational resources, promoting reproducibility and accelerating clinical translation.

  • 9 authors
·
May 31, 2025

Generative augmentations for improved cardiac ultrasound segmentation using diffusion models

One of the main challenges in current research on segmentation in cardiac ultrasound is the lack of large and varied labeled datasets and the differences in annotation conventions between datasets. This makes it difficult to design robust segmentation models that generalize well to external datasets. This work utilizes diffusion models to create generative augmentations that can significantly improve diversity of the dataset and thus the generalisability of segmentation models without the need for more annotated data. The augmentations are applied in addition to regular augmentations. A visual test survey showed that experts cannot clearly distinguish between real and fully generated images. Using the proposed generative augmentations, segmentation robustness was increased when training on an internal dataset and testing on an external dataset with an improvement of over 20 millimeters in Hausdorff distance. Additionally, the limits of agreement for automatic ejection fraction estimation improved by up to 20% of absolute ejection fraction value on out of distribution cases. These improvements come exclusively from the increased variation of the training data using the generative augmentations, without modifying the underlying machine learning model. The augmentation tool is available as an open source Python library at https://github.com/GillesVanDeVyver/EchoGAINS.

  • 8 authors
·
Feb 27, 2025

OCTCube-M: A 3D multimodal optical coherence tomography foundation model for retinal and systemic diseases with cross-cohort and cross-device validation

We present OCTCube-M, a 3D OCT-based multi-modal foundation model for jointly analyzing OCT and en face images. OCTCube-M first developed OCTCube, a 3D foundation model pre-trained on 26,685 3D OCT volumes encompassing 1.62 million 2D OCT images. It then exploits a novel multi-modal contrastive learning framework COEP to integrate other retinal imaging modalities, such as fundus autofluorescence and infrared retinal imaging, into OCTCube, efficiently extending it into multi-modal foundation models. OCTCube achieves best performance on predicting 8 retinal diseases, demonstrating strong generalizability on cross-cohort, cross-device and cross-modality prediction. OCTCube can also predict cross-organ nodule malignancy (CT) and low cardiac ejection fraction as well as systemic diseases, such as diabetes and hypertension, revealing its wide applicability beyond retinal diseases. We further develop OCTCube-IR using COEP with 26,685 OCT and IR image pairs. OCTCube-IR can accurately retrieve between OCT and IR images, allowing joint analysis between 3D and 2D retinal imaging modalities. Finally, we trained a tri-modal foundation model OCTCube-EF from 4 million 2D OCT images and 400K en face retinal images. OCTCube-EF attains the best performance on predicting the growth rate of geographic atrophy (GA) across datasets collected from 6 multi-center global trials conducted in 23 countries. This improvement is statistically equivalent to running a clinical trial with more than double the size of the original study. Our analysis based on another retrospective case study reveals OCTCube-EF's ability to avoid false positive Phase-III results according to its accurate treatment effect estimation on the Phase-II results. In sum, OCTCube-M is a 3D multi-modal foundation model framework that integrates OCT and other retinal imaging modalities revealing substantial diagnostic and prognostic benefits.

  • 12 authors
·
Aug 20, 2024

EchoLVFM: One-Step Video Generation via Latent Flow Matching for Echocardiogram Synthesis

Echocardiography is widely used for assessing cardiac function, where clinically meaningful parameters such as left-ventricular ejection fraction (EF) play a central role in diagnosis and management. Generative models capable of synthesising realistic echocardiogram videos with explicit control over such parameters are valuable for data augmentation, counterfactual analysis, and specialist training. However, existing approaches typically rely on computationally expensive multi-step sampling and aggressive temporal normalisation, limiting efficiency and applicability to heterogeneous real-world data. We introduce EchoLVFM, a one-step latent video flow-matching framework for controllable echocardiogram generation. Operating in the latent space, EchoLVFM synthesises temporally coherent videos in a single inference step, achieving a sim 50times improvement in sampling efficiency compared to multi-step flow baselines while maintaining visual fidelity. The model supports global conditioning on clinical variables, demonstrated through precise control of EF, and enables reconstruction and counterfactual generation from partially observed sequences. A masked conditioning strategy further removes fixed-length constraints, allowing shorter sequences to be retained rather than discarded. We evaluate EchoLVFM on the CAMUS dataset under challenging single-frame conditioning. Quantitative and qualitative results demonstrate competitive video quality, strong EF adherence, and 57.9% discrimination accuracy by expert clinicians which is close to chance. These findings indicate that efficient, one-step flow matching can enable practical, controllable echocardiogram video synthesis without sacrificing fidelity. Code available at: https://github.com/EngEmmanuel/EchoLVFM

BAAI Cardiac Agent: An intelligent multimodal agent for automated reasoning and diagnosis of cardiovascular diseases from cardiac magnetic resonance imaging

Cardiac magnetic resonance (CMR) is a cornerstone for diagnosing cardiovascular disease. However, it remains underutilized due to complex, time-consuming interpretation across multi-sequences, phases, quantitative measures that heavily reliant on specialized expertise. Here, we present BAAI Cardiac Agent, a multimodal intelligent system designed for end-to-end CMR interpretation. The agent integrates specialized cardiac expert models to perform automated segmentation of cardiac structures, functional quantification, tissue characterization and disease diagnosis, and generates structured clinical reports within a unified workflow. Evaluated on CMR datasets from two hospitals (2413 patients) spanning 7-types of major cardiovascular diseases, the agent achieved an area under the receiver-operating-characteristic curve exceeding 0.93 internally and 0.81 externally. In the task of estimating left ventricular function indices, the results generated by this system for core parameters such as ejection fraction, stroke volume, and left ventricular mass are highly consistent with clinical reports, with Pearson correlation coefficients all exceeding 0.90. The agent outperformed state-of-the-art models in segmentation and diagnostic tasks, and generated clinical reports showing high concordance with expert radiologists (six readers across three experience levels). By dynamically orchestrating expert models for coordinated multimodal analysis, this agent framework enables accurate, efficient CMR interpretation and highlights its potentials for complex clinical imaging workflows. Code is available at https://github.com/plantain-herb/Cardiac-Agent.

  • 21 authors
·
Apr 4